PS-G-03 Provisional Specifications for the Verification and Reverification of Mechanical Conversion Devices
PDF Format | Table of Contents
1. Scope
2. Authorization
3. Performance Requirements 3.1.2 For the purposes of clause 3.1.1, the following information shall be considered as objective evidence for the determination of the yearly maximum or minimum operating pressures of a gas distribution system:
Note: All measurements mentioned in this clause are to be made with measurement equipment of known accuracy. Table 1
3.1.3 Subject to clause 3.1.4, where no information has been provided regarding the characteristics of distribution system pressures to which the device will be subject, the test points for the base pressure conversion function accuracy of the device and the tolerance limits for the relative error of the pressure multiplier shall be as specified in Table 2. Table 2
Note: pmax symbolizes the device's maximum operating pressure. 3.1.4 In addition to the requirements of clauses 3.1.1 and 3.1.3, where the verification or reverification is performed at the device's operational location, the device shall be tested at its operating pressure at the time of the test and the relative error of the pressure multiplier shall fall within the tolerance interval of -2.0% to +1.0%. 3.1.5 Where a device fails to meet the requirements for verification or reverification, any subsequent reverification shall require a complete retesting of the device in accordance with clause 3.1.1 or clause 3.1.3 and, if applicable, clause 3.1.4. 3.1.6 For any verification or reverification, the value of the atmospheric pressure marked on the device shall fall within the tolerance interval established by the expression:
where
3.2 Base Temperature
Conversion Function Accuracy Tests Table 3
3.2.2 Subject to clause 3.2.3, for reverification at the operational location, the test points for the base temperature conversion function accuracy of the device and the tolerance limits for the relative error of the temperature multiplier shall be as specified in Table 4. Table 4
Note: to symbolizes the flowing gas temperature at the time of the test. 3.2.3 For modular-type base temperature conversion devices installed on rotary meters, where the test point temperatures of clause 3.2.2 cannot be achieved due to equipment or facility limitations, the device shall be tested at the flowing gas temperature and the relative error of the temperature multiplier shall not exceed ±0.5%. 3.2.4 Where a device fails to meet the requirements for verification or reverification, any subsequent reverification shall require a complete retesting of the device in accordance with clause 3.2.1 or clause 3.2.2, as applicable.
3.3 Combined Base Pressure and Base Temperature
Conversion 3.3.2 In addition, the algebraic sum of any pair of base pressure and base temperature conversion errors shall fall within the tolerance interval of:
3.4 Supercompressibility Correction Function
Accuracy Tests 3.4.2 Subject to clause 3.4.4, for a base pressure conversion device with a supercompressibility correction function, the device shall be verified or reverified in accordance with the requirements of clause 3.1 and the relative error of the supercompressibility-corrected pressure multiplier shall fall within the tolerance interval of:
3.4.3 Subject to clause 3.4.4, for a combination base pressure/base temperature conversion device with a supercompressibility correction function, the device shall be verified or reverified in accordance with the requirements of section 3.3 and the algebraic sum of any pair of the relative errors of the supercompressibility-corrected pressure multiplier and the temperature multiplier shall fall within the tolerance interval of:
3.4.4 For any reverification performed at the operational location, the flowing gas temperature at the time of the test and the marked values of the other gas parameters shall be used in the determination of the relative error of the supercompressibility-corrected pressure multiplier or the combined supercompressibility-corrected pressure and temperature multiplier, as the case may be.
3.5 Converted and Unconverted Register Accuracy
Tests
4. Other Requirements 4.2 All other requirements for the verification and reverification of mechanical conversion devices not relating to the performance of the devices remain unchanged.