| Column I
| Column II
| Column III
| Column IV
|
Item
| Energy-using Product
| ANSI/CGA/CIE/CSA/IES Standard
| Energy Efficiency Standard
| Completion Period
|
| | | | |
1.
| Clothes dryers
| CSA C361
| E = 0.3V + 59
| on or after the coming into force of these Regulations until April 30, 1995
|
2.
| Clothes dryers
| CSA C361
| CSA C361 Table 8.1
| on or after May 1, 1995
|
3.
| Clothes washers
| CSA C360
| E = 1.5V + 30.5
| on or after the coming into force of these Regulations until April 30, 1995
|
4.
| Clothes washers
| CSA C360
| CSA C360 clause 8.4
| on or after May 1, 1995 until December 30, 1998
|
4.1
| Clothes washers
| CSA C360-98
| CSA C360-98 clause 7.5
| on or after December 31, 1998
|
4.2
| Dehumidifiers
| CSA C749
| CSA C749 clause 4.2
| on or after December 31, 1998
|
5.
| Dishwashers
| CSA C373
| CSA C373 Table 7.1
| on or after the coming into force of these Regulations
|
6.
| Electric ranges that are freestanding or built-in appliances with one or more surface elements and one or more ovens
| CSA C358
| E=0.93V + 14.3
| on or after February 3, 1995 until December 31, 1999
|
6.1
| Electric ranges that are free-standing or built-in appliances with one or more surface elements and one or more ovens
| CSA C358-95
| E=0.93V + 14.3
| on or after January 1, 2000 until July 31, 2003
|
6.2
| Electric ranges that are free-standing or built-in appliances with one or more surface elements and one or more ovens
| CSA C358-03
| CSA C358-03 clause 8(a)
| on or after August 1, 2003
|
7.
| Electric ranges that are built-in or wall-mounted appliances with one or more ovens and no surface elements
| CSA C358
| E=38
| on or after February 3, 1995 until December 31, 1999
|
7.1
| Electric ranges that are built-in or wall-mounted appliances with one or more ovens and no surface elements
| CSA C358-95
| E=38
| on or after January 1, 2000 until July 31, 2003
|
7.2
| Electric ranges that are built-in or wall-mounted appliances with one or more ovens and no surface elements
| CSA C358-03
| CSA C358-03 clause 8(b)
| on or after August 1, 2003
|
8.
| Electric ranges that are counter-mounted appliances without ovens and with one or more surface elements on a conventional cooking top
| CSA C358
| E=34
| on or after February 3, 1995 until December 31, 1999
|
8.1
| Electric ranges that are counter-mounted appliances without ovens and with one or more surface elements on a conventional cooking top
| CSA C358-95
| E=34
| on or after January 1, 2000 until July 31, 2003
|
9.
| Electric ranges that are counter-mounted appliances without ovens and with one or more surface elements on a modular cooking top
| CSA C358
| E=43
| on or after February 3, 1995 until December 31, 1999
|
9.1
| Electric ranges that are counter-mounted appliances without ovens and with one or more surface elements on a modular cooking top
| CSA C358-95
| E=43
| on or after January 1, 2000 until July 31, 2003
|
9.2
| Electric ranges that are counter-mounted appliances without ovens and with one or more surface elements
| CSA C358-03
| CSA C358-03 clause 8(c)
| on or after August 1, 2003
|
10.
| Electric water heaters
| CSA C191.1
| CSA C191.1 clause 5
| on or after February 3, 1995
|
11.
| Fluorescent lamp ballasts
| CSA C654
| Power factor = 90% and CSA C654 clause 4.1 fourth column
| on or after February 3, 1995 until March 31, 2005
|
11.1
| Fluorescent lamp ballasts
| CSA C654
| Power factor = 90% and CSA C654 clause 4.1 fifth column
| on or after April 1, 2005
|
12.
| Freezers
| CSA C300
| CSA C300 Table 9.1
| on or after February 3, 1995 until June 30, 2001
|
12.1
| Freezers
| CSA C300-00
| CSA C300-00 Table 1, Column B
| on or after July 1, 2001
|
13.
| Gas furnaces with an input rate no greater than 65.92 kW (225 000 Btu/h) that use single-phase electric current
| CGA 2.3
| annual fuel utilization efficiency >=78%
| on or after February 3, 1995 until February 28, 2003
|
13.1
| Gas furnaces with an input rate no greater than 65.92 kW (225 000 Btu/h) that use single-phase electric current
| CSA 2.3
| annual fuel utilization efficiency >=78%
| on or after March 1, 2003
|
13.2
| Gas furnaces with an input rate no greater than 65.92 kW (225 000 Btu/h) that use three-phase electric current
| CGA 2.3
| annual fuel utilization efficiency >=78% or thermal efficiency >=80%
| on or after February 3, 1995 until February 28, 2003
|
13.3
| Gas furnaces with an input rate no greater than 65.92 kW (225 000 Btu/h) that use three-phase electric current
| CSA 2.3
| annual fuel utilization efficiency >=78% or thermal efficiency >=80%
| on or after March 1, 2003
|
13.4
| Gas furnaces with an input rate greater than 65.92 kW (225 000 Btu/h) but not greater than 117.23 kW (400 000 Btu/h)
| CGA 2.3
| thermal efficiency >=80%
| on or after February 3, 1995 until February 28, 2003
|
13.5
| Gas furnaces with an input rate greater than 65.92 kW (225 000 Btu/h) but not greater than 117.23 kW (400 000 Btu/h)
| CSA 2.3
| thermal efficiency >=80%
| on or after March 1, 2003
|
14.
| Gas ranges
| N/A
| no continuously burning pilot light
| on or after February 3, 1995
|
15.
| Gas water heaters
| CGA 4.1
| EF = 0.62-0.0005 V
| on or after February 3, 1995
|
15.1 and 15.2 [Repealed, SOR/2003-136, s. 8]
|
16.
| General service fluorescent lamps that are rapid-start straight-shaped fluorescent lamps with a nominal overall length of 1 200 mm (48 inches), a medium bi-pin base and a nominal power in excess of 35 W
| CSA C819
| average lamp efficacy >=75 lm/W and average colour rendering index >=69
| on or after February 1, 1996
|
16.1
| General service fluorescent lamps that are rapid-start straight-shaped fluorescent lamps with a nominal overall length of 1 200 mm (48 inches), a medium bi-pin base and a nominal power no greater than 35 W
| CSA C819
| average lamp efficacy >=75 lm/W and average colour rendering index >=45
| on or after February 1, 1996
|
16.2
| General service fluorescent lamps that are rapid-start straight-shaped fluorescent lamps with a nominal overall length of 2 400 mm (96 inches), a recessed double contact base, a nominal power in excess of 100 W and a nominal current of 0.8 A
| CSA C819
| average lamp efficacy >=80 lm/W and average colour rendering index >=69
| on or after February 1, 1996
|
16.3
| General service fluorescent lamps that are rapid-start straight-shaped fluorescent lamps with a nominal overall length of 2 400 mm (96 inches), a recessed double contact base, a nominal power no greater than 100 W and a nominal current of 0.8 A
| CSA C819
| average lamp efficacy >=80 lm/W and average colour rendering index >=45
| on or after February 1, 1996
|
16.4
| General service fluorescent lamps that are rapid-start U-shaped fluorescent lamps with a nominal overall length of not less than 560 mm (22 inches) but not more than 635 mm (25 inches), a medium bi-pin base and a nominal power in excess of 35 W
| CSA C819
| average lamp efficacy >=68 lm/W and average colour rendering index >=69
| on or after February 1, 1996
|
16.5
| General service fluorescent lamps that are rapid-start U-shaped fluorescent lamps with a nominal overall length of not less than 560 mm (22 inches) but not more than 635 mm (25 inches), a medium bi-pin base and a nominal power no greater than 35 W
| CSA C819
| average lamp efficacy >=64 lm/W and average colour rendering index >=45
| on or after February 1, 1996
|
16.6
| General service fluorescent lamps that are instant-start straight-shaped fluorescent lamps with a nominal overall length of 2 400 mm (96 inches), a single-pin base and a nominal power in excess of 65 W
| CSA C819
| average lamp efficacy >=80 lm/W and average colour rendering index >=69
| on or after February 1, 1996
|
16.7
| General service fluorescent lamps that are instant-start straight-shaped fluorescent lamps with a nominal overall length of 2 400 mm (96 inches), a single-pin base and a nominal power no greater than 65 W
| CSA C819
| average lamp efficacy >=80 lm/W and average colour rendering index >=45
| on or after February 1, 1996
|
17.
| ER lamps other than ER lamps with a nominal power of 50, 75 or 120 W
| CSA C862-01
| CSA C862-01 Table 1 second column
| on or after January 1, 2003
|
17.01
| ER lamps with a nominal power of 50, 75 or 120 W
| CSA C862-01
| CSA C862-01 Table 2 second column
| on or after January 1, 2003
|
17.02
| BR lamps
| CSA C862-01
| CSA C862-01 Table 1 second column
| on or after January 1, 2003
|
17.03
| General service incandescent reflector lamps
| CSA C862-01
| CSA C862-01 Table 1 second column
| on or after April 1, 1996
|
17.04 to 17.08 [Repealed, SOR/2003-136, s. 8]
|
17.09 to 17.14 [Repealed, SOR/2003-136, s. 9]
|
18.
| Ground-source heat pumps
| CSA C446
| CSA C446 Table 2
| on or after February 3, 1995 until December 30, 1998
|
18.1
| Ground-source heat pumps
| CSA C446-94
| CSA C446 Table 2
| on or after December 31, 1998
|
18.2
| Ice-makers
| CSA C742
| CSA C742 Table 1
| on or after December 31, 1998 until December 31, 1999
|
18.3
| Ice-makers
| CSA C742-98
| CSA C742-98 Table 2
| on or after January 1, 2000
|
19.
| Integrated over/under washer-dryers
| CSA C360 for the clothes washer component and CSA C361 for the clothes dryer component
| E = 1.5V + 30.5 for the clothes washer component and E = 0.3V + 59 for the clothes dryer component
| on or after the coming into force of these Regulations until April 30, 1995
|
20.
| Integrated over/under washer-dryers
| CSA C360 for the clothes washer component and CSA C361 for the clothes dryer component
| CSA C360 clause 8.4 for the clothes washer component and CSA C361 Table 8.1 for the clothes dryer component
| on or after May 1, 1995 until December 30, 1998
|
20.1
| Integrated over/under washer-dryers
| CSA C360-98 for the clothes washer component and CSA C361 for the clothes dryer component
| CSA C360-98 clause 7.5 for the clothes washer component and CSA C361 Table 8.1 for the clothes dryer component
| on or after December 31, 1998
|
21.
| Internal water loop heat pumps
| CSA C655
| CSA C655 Table 2
| on or after the coming into force of these Regulations
|
21.1
| Large air-conditioners
| CSA C746
| CSA C746 Table 6
| on or after December 31, 1998
|
21.2
| Large condensing units
| CSA C746
| CSA C746 Table 6
| on or after December 31, 1998
|
21.3
| Large heat pumps
| CSA C746
| CSA C746 Table 6
| on or after December 31, 1998
|
22.
| Oil-fired boilers
| CSA B212
| seasonal energy utilization efficiency >= 80%
| on or after December 31, 1998
|
22.1
| Oil-fired furnaces
| CSA B212
| seasonal energy utilization efficiency >= 78%
| on or after December 31, 1998
|
23.
| Oil-fired water heaters
| CSA B211
| CSA B211 clause 7
| on or after the coming into force of these Regulations
|
23.1
| Packaged terminal air-conditioners
| CSA C744
| CSA C744 Table 2
| on or after December 31, 1998
|
23.2
| Packaged terminal heat pumps
| CSA C744
| CSA C744 Table 2
| on or after December 31, 1998
|
24.
| Refrigerators or combination refrigerator-freezers
| CSA C300
| CSA C300 Table 9.1
| on or after February 3, 1995 until June 30, 2001
|
24.1
| Type 3 combination refrigerator-freezers with a total refrigerated volume >=410.65 L and <=521.10 L (>=14.5 cu. ft. and <=18.4 cu. ft.)
| CSA C300-00
| CSA C300-00 Table 1, Column A
| on or after July 1, 2001 until December 30, 2002
|
24.2
| Refrigerators or combination refrigerator-freezers other than Type 3 combination refrigerator-freezers, with a total refrigerated volume >=410.65 L and <=521.10 L (>=14.5 cu. ft. and <=18.4 cu. ft.)
| CSA C300-00
| CSA C300-00 Table 1, Column B
| on or after July 1, 2001
|
24.3
| Type 3 combination refrigerator-freezers with a total refrigerated volume >=410.65 L and <=521.10 L (>=14.5 cu. ft. and <=18.4 cu. ft.)
| CSA C300-00
| CSA C300-00 Table 1, Column B
| on or after December 31, 2002
|
25.
| Room air-conditioners
| CSA C368.1
| CSA C368.1 Table 1 third column
| on or after February 3, 1995 until December 31, 2002
|
25.1
| Room air-conditioners
| CSA C368.1
| CSA C368.1 Table 2 second column
| on or after January 1, 2003
|
26.
| Single package central air-conditioners that use single-phase electric current
| CSA C656
| seasonal energy efficiency ratio >= 9.7
| on or after February 3, 1995
|
27.
| Single package central air-conditioners that use three-phase electric current
| CSA C656
| seasonal energy efficiency ratio >= 9.7
| on or after December 31, 1998
|
28.
| Single package heat pumps that use single-phase electric current
| CSA C656
| seasonal energy efficiency ratio >= 9.7 and heating seasonal performance factor (Region V) >= 5.7
| on or after February 3, 1995
|
29.
| Single package heat pumps that use three-phase electric current
| CSA C656
| seasonal energy efficiency ratio >= 9.7 and heating seasonal performance factor (Region V) >= 5.7
| on or after December 31, 1998
|
30.
| Split-system central air-conditioners that use single-phase electric current
| CSA C273.3
| (a) seasonal energy efficiency ratio >= 9.0
| (a) on or after February 3, 1995 until December 30, 1998
|
| | | (b) seasonal energy efficiency ratio >= 10.0
| (b) on or after December 31, 1998
|
31.
| Split-system central air-conditioners that use three-phase electric current
| CSA C273.3
| seasonal energy efficiency ratio >= 10.0
| on or after December 31, 1998
|
32.
| Split-system heat pumps that use single-phase electric current
| CSA C273.3
| (a) seasonal energy efficiency ratio >= 9.0 and heating seasonal performance factor (Region V) >= 5.9
| (a) on or after February 3, 1995 until December 30, 1998
|
| | | (b) seasonal energy efficiency ratio >= 10.0 and heating seasonal performance factor (Region V) >= 5.9
| (b) on or after December 31, 1998
|
33.
| Split-system heat pumps that use three-phase electric current
| CSA C273.3
| seasonal energy efficiency ratio >= 10.0 and heating seasonal performance factor (Region V) >= 5.9
| |
34.
| Dry-type transformers, single-phase, 1.2 kV class
| CSA C802.2
| CSA C802.2 Table 1 third column
| on or after January 1, 2005
|
35.
| Dry-type transformers, single-phase, BIL 20-150 kV
| CSA C802.2
| CSA C802.2 Table 1 fourth column
| on or after January 1, 2005
|
36.
| Dry-type transformers, three-phase, 1.2 kV class
| CSA C802.2
| CSA C802.2 Table 1 seventh column
| on or after January 1, 2005
|
37.
| Dry-type transformers, three-phase, BIL 20-150 kV
| CSA C802.2
| CSA C802.2 Table 1 eighth column
| on or after January 1, 2005
|