Skip all menusSkip first menu   Department of Justice Canada / Ministère de la Justice CanadaGovernment of Canada
   
Français Contact us Help Search Canada Site
Justice Home Site Map Programs Proactive Disclosure Laws
Laws
Main Page
Glossary
Important Note
How to link
Printing Problems?
Easy Links
Constitution
Charter
Guide to Making Federal Acts and Regulations
Statutes by Title
Statutes by Subject
Advanced Search
Templates for advanced searching
Case Law
Federal and Provincial Case Law
Other
Table of Public Statutes and Responsible Ministers
Table of Private Acts
Index of Statutory Instruments
  Consolidated Statutes and Regulations
Enabling statute: Energy Efficiency Act
    Energy Efficiency Regulations
Disclaimer: These documents are not the official versions (more).
Source: http://laws.justice.gc.ca/en/E-6.4/SOR-94-651/97595.html
Updated to August 31, 2004

[Previous]


SCHEDULE I
(Section 4)
ENERGY EFFICIENCY STANDARDS

PART 1

Column I

Column II

Column III

Column IV

Item

Energy-using Product

ANSI/CGA/CIE/CSA/IES Standard

Energy Efficiency Standard

Completion Period

1.

Clothes dryers

CSA C361

E = 0.3V + 59

on or after the coming into force of these Regulations until April 30, 1995

2.

Clothes dryers

CSA C361

CSA C361 Table 8.1

on or after May 1, 1995

3.

Clothes washers

CSA C360

E = 1.5V + 30.5

on or after the coming into force of these Regulations until April 30, 1995

4.

Clothes washers

CSA C360

CSA C360 clause 8.4

on or after May 1, 1995 until December 30, 1998

4.1

Clothes washers

CSA C360-98

CSA C360-98 clause 7.5

on or after December 31, 1998

4.2

Dehumidifiers

CSA C749

CSA C749 clause 4.2

on or after December 31, 1998

5.

Dishwashers

CSA C373

CSA C373
Table 7.1

on or after the coming into force of these Regulations

6.

Electric ranges that are freestanding or built-in appliances with one or more surface elements and one or more ovens

CSA C358

E=0.93V + 14.3

on or after February 3, 1995 until December 31, 1999

6.1

Electric ranges that are free-standing or built-in appliances with one or more surface elements and one or more ovens

CSA C358-95

E=0.93V + 14.3

on or after January 1, 2000 until July 31, 2003

6.2

Electric ranges that are free-standing or built-in appliances with one or more surface elements and one or more ovens

CSA C358-03

CSA C358-03 clause 8(a)

on or after August 1, 2003

7.

Electric ranges that are built-in or wall-mounted appliances with one or more ovens and no surface elements

CSA C358

E=38

on or after February 3, 1995 until December 31, 1999

7.1

Electric ranges that are built-in or wall-mounted appliances with one or more ovens and no surface elements

CSA C358-95

E=38

on or after January 1, 2000 until July 31, 2003

7.2

Electric ranges that are built-in or wall-mounted appliances with one or more ovens and no surface elements

CSA C358-03

CSA C358-03 clause 8(b)

on or after August 1, 2003

8.

Electric ranges that are counter-mounted appliances without ovens and with one or more surface elements on a conventional cooking top

CSA C358

E=34

on or after February 3, 1995 until December 31, 1999

8.1

Electric ranges that are counter-mounted appliances without ovens and with one or more surface elements on a conventional cooking top

CSA C358-95

E=34

on or after January 1, 2000 until July 31, 2003

9.

Electric ranges that are counter-mounted appliances without ovens and with one or more surface elements on a modular cooking top

CSA C358

E=43

on or after February 3, 1995 until December 31, 1999

9.1

Electric ranges that are counter-mounted appliances without ovens and with one or more surface elements on a modular cooking top

CSA C358-95

E=43

on or after January 1, 2000 until July 31, 2003

9.2

Electric ranges that are counter-mounted appliances without ovens and with one or more surface elements

CSA C358-03

CSA C358-03 clause 8(c)

on or after August 1, 2003

10.

Electric water heaters

CSA C191.1

CSA C191.1
clause 5

on or after February 3, 1995

11.

Fluorescent lamp ballasts

CSA C654

Power factor = 90% and
CSA C654 clause 4.1 fourth column

on or after February 3, 1995 until March 31, 2005

11.1

Fluorescent lamp ballasts

CSA C654

Power factor = 90% and CSA C654 clause 4.1 fifth column

on or after April 1, 2005

12.

Freezers

CSA C300

CSA C300
Table 9.1

on or after February 3, 1995 until June 30, 2001

12.1

Freezers

CSA C300-00

CSA C300-00
Table 1, Column B

on or after July 1, 2001

13.

Gas furnaces with an input rate no greater than 65.92 kW (225 000 Btu/h) that use single-phase electric current

CGA 2.3

annual fuel utilization efficiency >=78%

on or after February 3, 1995 until February 28, 2003

13.1

Gas furnaces with an input rate no greater than 65.92 kW (225 000 Btu/h) that use single-phase electric current

CSA 2.3

annual fuel utilization efficiency >=78%

on or after March 1, 2003

13.2

Gas furnaces with an input rate no greater than 65.92 kW (225 000 Btu/h) that use three-phase electric current

CGA 2.3

annual fuel utilization efficiency >=78% or thermal efficiency >=80%

on or after February 3, 1995 until February 28, 2003

13.3

Gas furnaces with an input rate no greater than 65.92 kW (225 000 Btu/h) that use three-phase electric current

CSA 2.3

annual fuel utilization efficiency >=78% or thermal efficiency >=80%

on or after March 1, 2003

13.4

Gas furnaces with an input rate greater than 65.92 kW (225 000 Btu/h) but not greater than 117.23 kW (400 000 Btu/h)

CGA 2.3

thermal efficiency >=80%

on or after February 3, 1995 until February 28, 2003

13.5

Gas furnaces with an input rate greater than 65.92 kW (225 000 Btu/h) but not greater than 117.23 kW (400 000 Btu/h)

CSA 2.3

thermal efficiency >=80%

on or after March 1, 2003

14.

Gas ranges

N/A

no continuously burning pilot light

on or after February 3, 1995

15.

Gas water heaters

CGA 4.1

EF = 0.62-0.0005 V

on or after February 3, 1995

15.1 and 15.2 [Repealed, SOR/2003-136, s. 8]

16.

General service fluorescent lamps that are rapid-start straight-shaped fluorescent lamps with a nominal overall length of 1 200 mm (48 inches), a medium bi-pin base and a nominal power in excess of 35 W

CSA C819

average lamp efficacy >=75 lm/W and average colour rendering index >=69

on or after February 1, 1996

16.1

General service fluorescent lamps that are rapid-start straight-shaped fluorescent lamps with a nominal overall length of 1 200 mm (48 inches), a medium bi-pin base and a nominal power no greater than 35 W

CSA C819

average lamp efficacy >=75 lm/W and average colour rendering index >=45

on or after February 1, 1996

16.2

General service fluorescent lamps that are rapid-start straight-shaped fluorescent lamps with a nominal overall length of 2 400 mm (96 inches), a recessed double contact base, a nominal power in excess of 100 W and a nominal current of 0.8 A

CSA C819

average lamp efficacy >=80 lm/W and average colour rendering index >=69

on or after February 1, 1996

16.3

General service fluorescent lamps that are rapid-start straight-shaped fluorescent lamps with a nominal overall length of 2 400 mm (96 inches), a recessed double contact base, a nominal power no greater than 100 W and a nominal current of 0.8 A

CSA C819

average lamp efficacy >=80 lm/W and average colour rendering index >=45

on or after February 1, 1996

16.4

General service fluorescent lamps that are rapid-start U-shaped fluorescent lamps with a nominal overall length of not less than 560 mm (22 inches) but not more than 635 mm (25 inches), a medium bi-pin base and a nominal power in excess of 35 W

CSA C819

average lamp efficacy >=68 lm/W and average colour rendering index >=69

on or after February 1, 1996

16.5

General service fluorescent lamps that are rapid-start U-shaped fluorescent lamps with a nominal overall length of not less than 560 mm (22 inches) but not more than 635 mm (25 inches), a medium bi-pin base and a nominal power no greater than 35 W

CSA C819

average lamp efficacy >=64 lm/W and average colour rendering index >=45

on or after February 1, 1996

16.6

General service fluorescent lamps that are instant-start straight-shaped fluorescent lamps with a nominal overall length of 2 400 mm (96 inches), a single-pin base and a nominal power in excess of 65 W

CSA C819

average lamp efficacy >=80 lm/W and average colour rendering index >=69

on or after February 1, 1996

16.7

General service fluorescent lamps that are instant-start straight-shaped fluorescent lamps with a nominal overall length of 2 400 mm (96 inches), a single-pin base and a nominal power no greater than 65 W

CSA C819

average lamp efficacy >=80 lm/W and average colour rendering index >=45

on or after February 1, 1996

17.

ER lamps other than ER lamps with a nominal power of 50, 75 or 120 W

CSA C862-01

CSA C862-01
Table 1
second column

on or after January 1, 2003

17.01

ER lamps with a nominal power of 50, 75 or 120 W

CSA C862-01

CSA C862-01
Table 2
second column

on or after January 1, 2003

17.02

BR lamps

CSA C862-01

CSA C862-01
Table 1
second column

on or after January 1, 2003

17.03

General service incandescent reflector lamps

CSA C862-01

CSA C862-01
Table 1
second column

on or after April 1, 1996

17.04 to 17.08 [Repealed, SOR/2003-136, s. 8]

17.09 to 17.14 [Repealed, SOR/2003-136, s. 9]

18.

Ground-source heat pumps

CSA C446

CSA C446
Table 2

on or after February 3, 1995 until December 30, 1998

18.1

Ground-source heat pumps

CSA C446-94

CSA C446
Table 2

on or after December 31, 1998

18.2

Ice-makers

CSA C742

CSA C742
Table 1

on or after December 31, 1998 until December 31, 1999

18.3

Ice-makers

CSA C742-98

CSA C742-98
Table 2

on or after January 1, 2000

19.

Integrated over/under washer-dryers

CSA C360 for the clothes washer component
and
CSA C361 for the clothes dryer component

E = 1.5V + 30.5 for the clothes washer component
and
E = 0.3V + 59 for the clothes dryer component

on or after the coming into force of these Regulations until April 30, 1995

20.

Integrated over/under washer-dryers

CSA C360 for the clothes washer component
and
CSA C361 for the clothes dryer component

CSA C360 clause 8.4 for the clothes washer component
and
CSA C361 Table 8.1 for the clothes dryer component

on or after May 1, 1995 until
December 30, 1998

20.1

Integrated over/under washer-dryers

CSA C360-98 for the clothes washer component
and
CSA C361 for the clothes dryer component

CSA C360-98 clause 7.5 for the clothes washer component
and
CSA C361 Table 8.1 for the clothes dryer component

on or after December 31, 1998

21.

Internal water loop heat pumps

CSA C655

CSA C655
Table 2

on or after the coming into force of these Regulations

21.1

Large air-conditioners

CSA C746

CSA C746
Table 6

on or after December 31, 1998

21.2

Large condensing units

CSA C746

CSA C746
Table 6

on or after December 31, 1998

21.3

Large heat pumps

CSA C746

CSA C746
Table 6

on or after December 31, 1998

22.

Oil-fired boilers

CSA B212

seasonal energy utilization efficiency >= 80%

on or after December 31, 1998

22.1

Oil-fired furnaces

CSA B212

seasonal energy utilization efficiency >= 78%

on or after December 31, 1998

23.

Oil-fired water heaters

CSA B211

CSA B211
clause 7

on or after the coming into force of these Regulations

23.1

Packaged terminal air-conditioners

CSA C744

CSA C744
Table 2

on or after December 31, 1998

23.2

Packaged terminal heat pumps

CSA C744

CSA C744
Table 2

on or after December 31, 1998

24.

Refrigerators or combination refrigerator-freezers

CSA C300

CSA C300
Table 9.1

on or after February 3, 1995 until June 30, 2001

24.1

Type 3 combination refrigerator-freezers with a total refrigerated volume >=410.65 L and <=521.10 L (>=14.5 cu. ft. and <=18.4 cu. ft.)

CSA C300-00

CSA C300-00
Table 1,
Column A

on or after July 1, 2001 until December 30, 2002

24.2

Refrigerators or combination refrigerator-freezers other than Type 3 combination refrigerator-freezers, with a total refrigerated volume >=410.65 L and <=521.10 L (>=14.5 cu. ft. and <=18.4 cu. ft.)

CSA C300-00

CSA C300-00
Table 1,
Column B

on or after July 1, 2001

24.3

Type 3 combination refrigerator-freezers with a total refrigerated volume >=410.65 L and <=521.10 L (>=14.5 cu. ft. and <=18.4 cu. ft.)

CSA C300-00

CSA C300-00
Table 1,
Column B

on or after December 31, 2002

25.

Room air-conditioners

CSA C368.1

CSA C368.1
Table 1
third column

on or after February 3, 1995 until December 31, 2002

25.1

Room air-conditioners

CSA C368.1

CSA C368.1
Table 2
second column

on or after January 1, 2003

26.

Single package central air-conditioners that use single-phase electric current

CSA C656

seasonal energy efficiency ratio >= 9.7

on or after February 3, 1995

27.

Single package central air-conditioners that use three-phase electric current

CSA C656

seasonal energy efficiency ratio >= 9.7

on or after December 31, 1998

28.

Single package heat pumps that use single-phase electric current

CSA C656

seasonal energy efficiency ratio >= 9.7 and heating seasonal performance factor (Region V) >= 5.7

on or after February 3, 1995

29.

Single package heat pumps that use three-phase electric current

CSA C656

seasonal energy efficiency ratio >= 9.7 and heating seasonal performance factor (Region V) >= 5.7

on or after December 31, 1998

30.

Split-system central air-conditioners that use single-phase electric current

CSA C273.3

(a) seasonal energy efficiency ratio >= 9.0

(a) on or after February 3, 1995 until December 30, 1998

(b) seasonal energy efficiency ratio >= 10.0

(b) on or after December 31, 1998

31.

Split-system central air-conditioners that use three-phase electric current

CSA C273.3

seasonal energy efficiency ratio >= 10.0

on or after December 31, 1998

32.

Split-system heat pumps that use single-phase electric current

CSA C273.3

(a) seasonal energy efficiency ratio >= 9.0 and heating seasonal performance factor (Region V) >= 5.9

(a) on or after February 3, 1995 until December 30, 1998

(b) seasonal energy efficiency ratio >= 10.0 and heating seasonal performance factor (Region V) >= 5.9

(b) on or after December 31, 1998

33.

Split-system heat pumps that use three-phase electric current

CSA C273.3

seasonal energy efficiency ratio >= 10.0 and heating seasonal performance factor (Region V) >= 5.9

34.

Dry-type transformers, single-phase, 1.2 kV class

CSA C802.2

CSA C802.2
Table 1
third column

on or after January 1, 2005

35.

Dry-type transformers, single-phase, BIL 20-150 kV

CSA C802.2

CSA C802.2
Table 1
fourth column

on or after January 1, 2005

36.

Dry-type transformers, three-phase, 1.2 kV class

CSA C802.2

CSA C802.2
Table 1
seventh column

on or after January 1, 2005

37.

Dry-type transformers, three-phase, BIL 20-150 kV

CSA C802.2

CSA C802.2
Table 1
eighth column

on or after January 1, 2005

PART 2

Column I

Column II

Energy Efficiency Standard (Percentage)

Item

Power in HP

Open

Enclosed

2 pole

4 pole

6 pole

2 pole

4 pole

6 pole

1.

1

75.5

82.5

80.0

75.5

82.5

80.0

2.

1.5

82.5

84.0

84.0

82.5

84.0

85.5

3.

2

84.0

84.0

85.5

84.0

84.0

86.5

4.

3

84.0

86.5

86.5

85.5

87.5

87.5

5.

5

85.5

87.5

87.5

87.5

87.5

87.5

6.

7.5

87.5

88.5

88.5

88.5

89.5

89.5

7.

10

88.5

89.5

90.2

89.5

89.5

89.5

8.

15

89.5

91.0

90.2

90.2

91.0

90.2

9.

20

90.2

91.0

91.0

90.2

91.0

90.2

10.

25

91.0

91.7

91.7

91.0

92.4

91.7

11.

30

91.0

92.4

92.4

91.0

92.4

91.7

12.

40

91.7

93.0

93.0

91.7

93.0

93.0

13.

50

92.4

93.0

93.0

92.4

93.0

93.0

14.

60

93.0

93.6

93.6

93.0

93.6

93.6

15.

75

93.0

94.1

93.6

93.0

94.1

93.6

16.

100

93.0

94.1

94.1

93.6

94.5

94.1

17.

125

93.6

94.5

94.1

94.5

94.5

94.1

18.

150

93.6

95.0

94.5

94.5

95.0

95.0

19.

175

94.5

95.0

94.5

95.0

95.0

95.0

20.

200

94.5

95.0

94.5

95.0

95.0

95.0

PART 3

Column I

Column II

Energy Efficiency Standard (Percentage)

Item

Power in kW

Open

Enclosed

2 pole

4 pole

6 pole

2 pole

4 pole

6 pole

1.

0.75

75.5

82.5

80.0

75.5

82.5

80.0

2.

1.1

82.5

84.0

84.0

82.5

84.0

85.5

3.

1.5

84.0

84.0

85.5

84.0

84.0

85.5

4.

2.2

84.0

84.0

86.5

85.5

84.0

87.5

5.

3.0

84.0

84.0

86.5

85.5

84.0

87.5

6.

3.7

85.5

87.5

87.5

87.5

87.5

87.5

7.

4.0

85.5

87.5

87.5

87.5

87.5

87.5

8.

5.5

87.5

88.5

88.5

88.5

89.5

89.5

9.

7.5

88.5

89.5

90.2

89.5

89.5

89.5

10.

11

89.5

91.0

90.2

90.2

91.0

90.2

11.

15

90.2

91.0

91.0

90.2

91.0

90.2

12.

18.5

91.0

91.7

91.7

91.0

92.4

91.7

13.

22

91.0

92.4

92.4

91.0

92.4

91.7

14.

30

91.7

93.0

93.0

91.7

93.0

93.0

15.

37

92.4

93.0

93.0

92.4

93.0

93.0

16.

45

93.0

93.6

93.6

93.0

93.6

93.6

17.

55

93.0

94.1

93.6

93.0

94.1

93.6

18.

75

93.0

94.1

94.1

93.6

94.5

94.1

19.

90

93.6

94.5

94.1

94.5

94.5

94.1

20.

110

93.6

95.0

94.5

94.5

95.0

95.0

21.

132

94.5

95.0

94.5

95.0

95.0

95.0

22.

150

94.5

95.0

94.5

95.0

95.0

95.0

SOR/95-173, s. 3(F); SOR/95-522, ss. 5, 6; SOR/97-529, ss. 7 to 9; SOR/99-25, ss. 5 to 11; err.(E), Vol. 133, No. 7; SOR/2001-150, ss. 2 to 5; SOR/2003-136, ss. 7 to 11; SOR/2003-321, ss. 5 to 8.

SCHEDULE II
(Section 6)
EXPLANATION FOR ELEMENTS ON HOUSEHOLD APPLIANCE ENERGY EFFICIENCY LABEL

GRAPHIC IS NOT DISPLAYED, SEE SOR/99-25, S. 12

SOR/99-25, s. 12.

SCHEDULE III
(Section 6)
EXPLANATION FOR ELEMENTS ON ROOM AIR-CONDITIONER ENERGY EFFICIENCY LABEL

GRAPHIC IS NOT DISPLAYED, SEE SOR/99-25, S. 12

SOR/99-25, s. 12.


[Next]