1. APPLICATION OF STANDARD 1.1 This Standard shall apply on all tracks owned or operated on by a railway company. 2. INTERPRETATION 2.1 In this Standard: “Chief Engineer” means a person occupying the position of Chief Engineer, or in companies not having a Chief Engineer the senior official designated for this purpose. 3. STANDARD CLEARANCES Subject to section 4:
4. LESS THAN STANDARD CLEARANCES 4.1 All existing structures, bridges, snowsheds, overhead timber bridges and tunnels which met previous clearance requirements, but encroach within the clearance limits prescribed herein, shall not be considered as having less than standard clearances and shall be permitted to remain until the restrictive feature is modified or replaced. 4.2 Clearances not meeting the requirements of section 3 above, are permitted in the following circumstances:
4.3
4.4 At locations described in subsection 4.2 paragraphs (b) and (c) and where the Chief Engineer has approved a less than standard clearance pursuant to sections 3.1 and 4.3, a less than standard clearance sign, as shown in Appendix “A”, shall be erected and maintained adjacent to the track on which the restriction is located and at an adequate distance from the restriction. Where physical impediments preclude the erection of such a sign, the less than standard clearance will be identified in special instructions. 4.5 Requests for approval of less than standard clearances shall be submitted to the Chief Engineer and shall include the following information:
4.6 Employees must not ride the side or above the roof of a moving engine or car when passing side and/or overhead restrictions. 5. TRACK CENTRES 5.1 Subject to subsection 5.2, all trackage built or rearranged after the coming into force of this Standard shall, comply with the minimum distances between track centre lines with due allowance for superelevation and curvature and shall be as follows: (a) Main tracks 3.96 m (13 feet) 5.2
5.3 The minimum distance between track centre lines shall be increased to account for curvature and superelevation as follows:
6. SIDING AGREEMENTS 6.1 Siding agreements shall contain a clause setting out the requirements of this Standard. 7. WIRES AND CONDUCTORS 7.1 Canadian Standards Association Standard C22.3 shall be used for minimum clearances. 8. NOTIFYING THE MINISTER OF TRANSPORT 8.1 The Minister of Transport will be notified, in writing, of:
|
![]() |
![]() |
|||||||
|
Transport Canada |
Pacific Region |
Prairie & Northern Region |
Ontario Region |
Quebec Region |
Atlantic Region |
About us |
Our offices |
Organization and senior management |
Departmental publications |
Programs and services |
Acts |
Regulations |
[More...] |
Media room |
Advisories |
Contacts |
e-news |
News releases |
Photo gallery | Reference centre |
Speeches |
[More...] |
Emergencies |
Emergencies and crises |
Emergency preparedness |
Security |
Transport of dangerous goods |
[More...] |
Air |
Our offices |
Passengers |
Pilots |
Flight instructors |
Maintenance technicians |
Commercial airlines |
Security |
Transport of dangerous goods |
[More...] |
Marine |
Our offices |
Small commercial vessels |
Large commercial vessels |
Pleasure craft |
Marine security |
Marine infrastructure |
Transport of dangerous goods |
[More...] |
Rail |
Our offices |
Safety at railway crossings |
Rail infrastructure |
Transport of dangerous goods |
[More...] |