Institute for National Measurement Standards

Electrical Standards - Calibration Services

Ordering Calibrations Services

The Electrical Standards Group develops and maintains Canada's national standards of electrical measurement and disseminates the corresponding electrical units throughout Canada. The Group provides technical support to the Canadian Laboratory Assessment Service (CLAS) in the area of electrical standards and participates with other national and international organizations in activities related to electrical standards.

Contact: Dr. Dave Inglis
Tel. 613-991-5650

The calibration services of the Group cover:

  • DC resistance from 10 µto 100 T
  • DC voltage from 100 µV to 100 kV
  • AC voltage (ac-dc difference) from 0.5 V to 500 V and 2 Hz to 500 MHz*
  • AC resistance (shunts) from 25 mto 100from dc to 5 kHz*
  • AC capacitance from 0.001pF to 1 µF at 1 kHz
  • AC inductance from 1 µH to 10 H at 1 kHz
  • RF voltage (ac-dc difference) from 1 µV to 100 V and from 1 MHz to 1 GHz*
  • RF impedance (Z/Zo) from 0.5 to 2.0 from 250 MHz to 18 GHz
  • RF attenuation to 60 dB at frequencies from 1 MHz to 36 GHz
  • RF power from 1 µW to 10 mW from 1 MHz to 40 GHz
    *not all combinations are available

A number of other measurements can be performed by special arrangement.

The Electrical Standards Group usually begins calibrations only in April, May, June, October, November, and December. Calibrations may begin in other months, but only by special arrangement. To assure minimum calibration delays, please consult with the Group before sending calibration equipment to NRC. Measurements are normally performed at room temperature, typically 20°C to 23°C, and approximately 40% relative humidity, unless otherwise specified.

Fees For Service

Ordering Calibrations Services NEW procedures effective March 23, 2006.

A33-02-00-00
Custom Electrical Measurement or Services
Fee on request
Contact Dr. Dave Inglis for further information
A33-02-00-01
Handling Fee
$200
A charge is levied for any instrument found to be unsuitable for calibration. This fee covers opening, inspection, and return and is based on the work done prior to discovery of the fault.

Direct Current and Low Frequency Measurements

 DC Voltage Measurements
 Resistance Measurements
 Inductance Measurements
 Capacitance Measurements
 AC-DC Transfer

Radio Frequency (RF) & Microwave Measurements

 RF Attenuation
 RF Impedence
 RF Voltage
 RF Power

DC Voltage Measurements

Standard Cells in Thermostated Enclosure (A33-02-01-01 to A33-02-01-02)
A33-02-01-01
Enclosure (up to four saturated standard cells)
$1210
A determination is made of the emf of up to four saturated standard cells in a self-contained, temperature-controlled
A33-02-01-02
$165
Additional cell

Standard cells normally require from one to three weeks to stabilize under laboratory conditions of constant temperature followed by a period of about two weeks for calibration. The calibration report will quote the mean value of the electromotive force (emf) observed during this latter period, in terms of the unit of emf maintained by NRC, and will provide an indication of the variations observed. If appreciable, the change observed during the initial stabilizing period will also be reported.

Zener Reference Standards (A33-02-01-03 to A33-02-01-07)
A33-02-01-03
First EMF
$1210
This service determines the emf of a Zener reference standard.
A33-02-01-04
Additional EMF with the same EMF common
$165
This service is provided at a reduced rate for each additional emf, up to four emfs per unit, referenced to the same common, when performed at the same time and under the same conditions as
A33-02-01-03 above.
A33-02-01-05
Additional EMF with a different EMF common
$275
This service covers, at a reduced rate, each additional isolated emf, up to four emfs per unit, referenced to a separate common (or low), when performed at the same time and under the same conditions as
A33-02-01-03 above.
A33-02-01-06
Additional EMFs (more than four per unit)
$605
Each additional emf (more than four emfs per unit) is determined, at a reduced rate, when measured at the same time and under the same conditions as A33-02-01-04 or A33-02-01-05 above.

Resistance Measurements

DC Resistors (A33-02-03-01 to A33-02-03-04)
A33-02-03-01
Resistor < 1 M, at
25 °C (in oil) or 23 °C (in air)

$605
This service determines the resistance of a reference standard resistor less than 1 M(decimal multiple or sub-multiple of 1 ) in oil at
25°C or in air at 23°C.
A33-02-03-02
Resistor <1 M, at another temperature
$715
This is the same service as A33-02-03-01 above, performed at a specified temperature in the range 20°C to 35°C.
NOTE: 1 M, only resistors that are mounted in a shielded enclosure with a permanent identifying number and with suitable terminations are accepted for calibration.
A33-02-03-03
Resistor 1 M
$825
This service determines the resistance of a resistor of 1 Mor greater in air at 23 °C or 25 °C at a specified test voltage (1000 V maximum).
A33-02-03-04
Resistor, additional test voltages
$220

Determinations will be made at additional test voltages at the same time and under the same conditions as for A33-02-03-03, at a reduced rate per specified test voltage.

Resistors for Current Measurements (Current Shunts)
Measurements may be made at direct currents up to 100 A.
A33-02-04-01
One resistor or range
$660
The resistance of a single resistor or one range of a multi-range resistor is measured at room temperature or 23°C.
A33-02-04-02
One resistor or range, Additional Temperatures
$770
The resistance of the resistor or the range of the multi-range resistor used in A33-02-04-01 above is measured at one or more controlled temperatures other than room temperature.
A33-02-04-03
Multi-range resistor, additional Range
$220
This service measures another range of the multi-range resistor used in A33-02-04-01 above. The service can only be carried out at the same time and under the same conditions as the above test.
A33-02-04-04
One Resistor or range, additional currents
$220
The resistance of the resistor or the range of the multi-range resistor used in A33-02-04-01 above is measured at one or more additional currents. This service applies only when carried out at the same time and under the same conditions as for the original test.
A33-02-04-05
One resistor or range, additional time intervals
$220
The resistance of the resistor or the range of the multi-range resistor used in A33-02-04-01 above is measured at one or more additional time intervals of electrification. This service applies only when carried out at the same time and under the same conditions as for the original test.



Inductance Measurements
A33-02-05-01
Fixed inductor, one frequency
$385
This service determines the series self inductance of a fixed inductor at one frequency.

Inductors with non-magnetic cores are normally measured at a specified temperature in the range 20 °C to 25°C and at frequencies of 100 Hz, 400 Hz, or 1000 Hz.



Capacitance Measurements
A33-02-06-01
3-Terminal fixed capacitance
$385
The 3-terminal capacitance of a fixed standard capacitor is measured at one frequency.
A33-02-06-02
2-Terminal fixed capacitance
$495
The 2-terminal capacitance of a fixed standard capacitor is measured at one frequency.
A33-02-06-03
Fused silica dielectric capacitor
$715
The 3-terminal capacitance of a 10 pF and/or 100 pF fused silica dielectric capacitor is measured in its own temperature controlled enclosure at 1592 Hz.

Capacitance is normally measured at a specified temperature in the range 20 °C to 25 °C and at frequencies of 100 Hz, 400 Hz, or 1000 Hz.

AC-DC Transfer
A33-02-07-01
AC-DC Transfer, one Rrange and frequency
$652.50
The ac-dc difference is determined at one voltage less than or equal to
1000 V and at one frequency less than or equal to 1 MHz.
A33-02-07-02
AC-DC Transfer, additional range or frequency
$145
The ac-dc difference is measured on one additional range of voltage (1000 V maximum) or current (20 A maximum) at one additional frequency. This service is available only when performed at the same time and under the same conditions as A33-02-07-01.
A33-02-07-04
Fluke Model 792A
$13,050
Full calibration of Fluke model 792A according to manufacturers specifications.
A33-02-07-05
Fluke Model 792A
Fee on request
Partial calibration of Fluke model 792A according to manufacturer specifications.

Thermal transfer standards and thermal converters can be calibrated between 0.002 volt and 1000 volts at frequencies between 10 Hz and 1 MHz. Not all combinations of frequency and voltage are available. Alternating current shunts normally used with the thermal devices described above may be calibrated up to 20 A and 30 kHz.


Radio Frequency (RF) & Microwave Measurements

RF Attenuation
A33-02-08-01
Attenuator insertion loss
$1160
A determination is made of the insertion loss of an attenuator at one frequency within the range 60 MHz to 36 GHz.
A33-02-08-02
Additional attenuators (waveguide)
$435
Insertion loss is determined for additional attenuators (if waveguide) at the frequency already used for measurement of the first attenuator. This service is available only when performed at the same time and under the same conditions as A33-02-08-01.
A33-02-08-03
Additional attenuators (coaxial)
$435
Insertion loss is determined for additional attenuators (if coaxial) at the frequency already used for measurement of the first attenuator. This service is available only when performed at the same time and under the same conditions as A33-02-08-01.
A33-02-08-04
Attenuator insertion loss, ldditional lrequency
$435
The insertion loss of one attenuator is determined at each additional frequency in the octave or waveguide frequency band already used for measurement in A33-02-08-01. This service is available only when performed at the same time and under the same conditions as the original test.
A33-02-08-05
Attenuation, variable or switched attenuator, 60 MHz - 36 GHz
$1160
A determination is made of the attenuation of one differential setting of a variable or switched attenuator at one frequency in the range
60 MHz to 36 GHz.
A33-02-08-06
Attenuator, additional differential setting,
60 MHz - 36 GHz

$435
This service covers each additional differential setting at the frequency already used for measurement during the initial test (A33-02-08-05). It is available only when performed at the same time and under the same conditions as the original test.
A33-02-08-07
Variable attenuator, additional insertion Loss
$435
The insertion loss is determined at one setting of a variable attenuator, at the frequency already used for measurement in A33-02-08-05. This service is available only when performed at the same time and under the same conditions as the original test.
A33-02-08-08
Attenuator, additional frequency
$435
Each additional frequency is determined in the frequencyband already used for measurement of the first differential setting in A33-02-08-05. This service is available only when performed at the same time and under the same conditions as the original test.
A33-02-08-09
Attenuation, 1 MHz - 60 MHz
$870
A determination is made of one attenuation value at one frequency within the range 1 MHz to 60 MHz.
A33-02-08-10
Additional attenuation values
$72.50
Additional attenuation values can be determined at the same frequency for the attenuator used in A33-02-08-09, if measured at the same time and under the same conditions as the original test.



RF Impedance
A33-02-09-01
Reflection coefficient, coaxial termination
$385
This service determines the complex reflection coefficient of a coaxial termination with precision connector in one of the following frequency bands:

0.5 GHz to 1 GHz 4 GHz to 8 GHz
1 GHz to 2 GHz 8 GHz to 12.4 GHz
2 GHz to 4 GHz 12 GHz to 18 GHz
A33-02-09-02
Reflection coefficient, additional terminations
$275
This service determines the complex reflection coefficient of additional coaxial terminations in the same frequency band. It must take place at the same time and under the same conditions as A33-02-09-01.



RF Voltage
A33-02-10-01
Thermal voltage converter
$542
The ac-dc difference of a thermal voltage converter is determined at one frequency within the range 0.1 MHz to
100 MHz.
A33-02-10-02
Additional frequencies or thermal voltage converters
$155
This service measures the ac-dc difference at additional frequencies or additional converters at the same frequency as that used in A33-02-10-01. These measurements must be taken at the same time and under the same conditions as above.
A33-02-10-03
Micropotentiometer
On request
The ac-dc difference of a micropotentiometer is determined at one voltage level at 30 MHz.
A33-02-10-04
Micropotentiometer, other frequencies
On request
A determination is made of the ac-dc difference of a micropotentiometer at one voltage level at each frequency other than 30 MHz, but less than 1 GHz. This service is available only at the same time and under the same conditions as
A33-02-10-03.
A33-02-10-05
Additional micropotentiometers
On request
The ac-dc difference of additional micropotentiometers is measured at the frequency used for measurement in
A33-02-10-03. All micropotentiometers must be supplied at the same time.



RF Power
A33-02-11-01A
Coaxial bolometer mount
$495
This service measures the effective efficiency and calibration factor of a coaxial bolometer mount or power sensor at one frequency within the range 0.1 MHz to 250 MHz
A33-02-11-02A
Coaxial bolometer mount, additional device
$220
Additional coaxial bolometer mounts or power sensors are measured at the frequency used to measure the coaxial bolometer in
A33-02-11-01A, when supplied at the same time and measured under the same conditions.
A33-02-11-03A
Coaxial bolometer mounts, additional frequencies
$220
The coaxial bolometers, or power sensors, used in A33-02-11-01A and/or
A33-02-11-02A are measured at another frequency.
A33-02-11-01B
Coaxial bolometer mount
$385
This service measures the effective efficiency and calibration factor of a coaxial bolometer mount or power sensor at one frequency within the range 0.3 GHz to 18 GHz, 18 GHz to
26.5 GHz, 26.5 GHz to 40 GHz and 30 GHz to 50 GHz
A33-02-11-02B
Coaxial bolometer mount, additional device
$220
Additional coaxial bolometer mounts or power sensors are measured at the frequency used to measure the coaxial bolometer in A33-02-11-01B, when supplied at the same time and measured under the same conditions.
A33-02-11-03B
Coaxial bolometer mounts, additional frequencies
$220
The coaxial bolometers, or power sensors, used in
A33-02-11-01B and/or A33-02-11-02B are measured at another frequency within the same band.
A33-02-11-04
Transfer Standard
On request
Measurement of K2 and Sg of a coaxial or waveguide power transfer standard (directional coupler with a sensor on the sidearm)
A33-02-11-08
Reference source in an RF power meter,
50 MHz

$165
This service measures the power available from a reference source in an RF power meter at the frequency of 50 MHz.
A33-02-11-10
Waveguide thermistor mount
$385
Effective efficiency and calibration factor of a waveguide thermistor mount or power transfer standard (terminated on a load) at one frequency in a band (WR-90, WR-62, WR-42, WR-28, WR-22).
A33-02-11-12
Waveguide thermistor mount, additional device
$220
Each additional waveguide thermistor mount or power transfer standard (terminated on a load) used in
A33-02-11-10.

A33-02-11-14
Waveguide thermistor mount, additional frequency
$220

Each additional frequency within the same band for the waveguide thermistor mount or power transfer standard (terminated) used in A33-02-11-12.