| |
Technical Requirements for Energy-Using Products
Part Two
Household appliances
Clothes dryer
Clothes washers
Dishwashers
Electric ranges
Freezers
Gas ranges
Integrated clothes washer-dryers
Refrigerators and combination refrigerator-freezers
APPLIES TO
standard and compact electrically
operated and electrically heated
household tumble-type clothes dryers.
TEST STANDARD
CAN/CSA-C361-92
COMPLIANCE DATE
May 1, 1995, for standard clothes dryers
December 31, 1998, for compact clothes dryers
ENERGUIDE LABEL
required
not required
ENERGUIDE DIRECTORY
available
not available
|
Clothes dryers
PRODUCT CLASS |
MINIMUM EF
May 1, 1995
|
|
(kg/kWh) |
(lb/kWh) |
Standard clothes dryer
( 125-litre capacity)
|
1.36 |
3.01 |
|
December 31, 1998 |
Compact clothes dryer
(< 125-litre capacity)
|
|
|
120 V |
1.42 |
3.13 |
240 V |
1.31 |
2.90 |
Where EF = Energy Factor |
Requirements for the energy efficiency report, as listed in Schedule IV of the Regulations
- type of product (clothes dryer);
- brand name;
- model number;
- manufacturer;
- name of the organization or province that carried out the clothes dryer verification and authorized the verification mark that will be affixed to the clothes dryer;
- annual energy consumption in kWh (based on 416 cycles per year);
- energy factor in kg/kWh;
- test group (size category: compact or standard);
- nominal voltage;
- volume of drum in litres; and
- type of drying control (i.e., timed, auto-temperature or auto-moisture).
|
APPLIES TO
standard or compact electrically operated household clothes washers that are top- or front-loaded, and that have an internal control system that regulates the water temperature without the need for user intervention subsequent to initiation of machine operation.
TEST STANDARD
1. CAN/CSA-C360-92
2. CAN/CSA-C360-03
COMPLIANCE DATE
1. May 1, 1995
2. January 1, 2004
and January 1, 2007
ENERGUIDE LABEL
required
not required
ENERGUIDE DIRECTORY
available
not available
|
Clothes washers
PRODUCT CLASS |
MINIMUM EF
(L/kWh/cycle)
|
|
January 1, 2004 |
January 1, 2007 |
Vertical-axis compact
(less than 45 L capacity)
|
18.40 |
18.40 |
Vertical-axis standard (45 L or greater capacity) |
29.45 |
35.68 |
Horizontal-axis* |
29.45 |
35.68 |
Suds-saving* |
NA |
NA |
MEF = Modified Energy Factor |
* These product classes shall be equipped with an unheated rinse water option. |
Requirements for the energy efficiency report, as listed in Schedule IV of the Regulations
- type of product (clothes washer);
- brand name;
- model number;
- manufacturer;
- name of the organization or province that carried out the clothes washer verification and authorized the verification mark that will be affixed to the clothes washer;
- annual energy consumption in kWh (based on 392 cycles per year);
- modified, energy factor in L/kWh/cycle;
- test group size category: compact or standard;
- volume of clothes basket in litres;
- water consumption factor in L/cycle/L;
- maximum wash temperature available: less than or equal to 57.2 °C or greater then
57.2 °C;
- wash-rinse temperature selections featured as listed in Table 5 of CSA 360-03;
- water fill control systems featured: manual or adaptive.
|
APPLIES TO
electrically operated automatic household dishwashers that are not commercial, industrial or institutional machines.
TEST STANDARD
1.2. CAN/CSA-C373-92
2. 10 CFR 430.23
10 CFR AppendixC
US Federal Register
COMPLIANCE DATE
1. February 3, 1995
2. January 1, 2004
ENERGUIDE LABEL
required
not required
ENERGUIDE DIRECTORY
available
not available
|
Dishwashers
PRODUCT CLASS |
MINIMUM EF
January 1, 2004
|
|
(cycle/kWh) |
Compact dishwashers
(holds, less than 8 place settings and 6 serving dishes)
|
0.62 |
Standard dishwashers
|
0.46 |
Where EF = Energy Factor (cycles per kilowatt hour) |
Requirements for the energy efficiency report, as listed in Schedule IV of the Regulations
- type of product (dishwasher);
- brand name;
- model number;
- manufacturer;
- name of the organization or province that carried out the dishwasher verification and authorized the verification mark that will be affixed to the dishwasher;
- annual energy consumption in kWh (kilowatt hours per cycle multiplied by 215 cycles/year);
- test group type and size category: built-in or portable; compact or standard
- volume of hot water used in litres; and
- energy factor in cycles/kWh
- drying of options offered: dry heat or heat on/heat off.
|
APPLIES TO
household ranges that are:
– free-standing or built-in appliances with one or more surface elements
and one or more ovens;
– built-in or wall-mounted appliances equipped with one or more ovens and no surface elements;
– counter-mounted appliances without ovens with one or more surface elements
but does not include the following:
– microwave cooking appliance;
– portable appliances designed for an electrical supply of 120 volts;
TEST STANDARD
1. CAN/CSA-C358-95
2. CAN/CSA-C358-03
COMPLIANCE DATE
1. February 3, 1995
2. August 1, 2003
ENERGUIDE LABEL
required
not required
ENERGUIDE DIRECTORY
available
not available
|
Electric ranges
PRODUCT CLASS |
MAXIMUM E
August 1, 2003
|
Ranges
Free-standing or built-in ranges with one or more surface elements and one or more ovens |
2.0V + 458 |
Ovens
Built-in or wall-mounted ranges without surface elements and with one or more ovens |
2.0V + 200 |
Cooktops
Counter-mounted ranges without ovens and with one or more surface elements on a conventional (i.e., not modular) cooktop
|
258 |
Where
V = Volume of oven in litres
E = Maximum allowable energy consumption in kWh/year
|
Requirements for the energy efficiency report, as listed in Schedule IV of the Regulations
- type of product (electric range);
- brand name;
- model number;
- manufacturer;
- name of the organization or province that carried out the electric range verification and authorized the verification mark that will be affixed to electric range;
- annual energy consumption in kWh;
- test group, (type for range and ovens: self-cleaning or non-selfcleaning);
size category for ranges: width 24 inches or 30 inches)
- annual clock energy consumption in kWh.
For free-standing or built-in ranges with one or more surface elements and one or more ovens:
- whether the range is free-standing or built-in;
- volume of usable oven space in litres;
- whether the cooktop is conventional, smooth, solid, modular or tungsten halogen.
- whether the oven is single or double;
- whether the oven baking mode is normal bake or normal bake with forced convection.
For built-in or wall-mounted ranges with one or more ovens and no surface elements:
- whether the range is built-in or wall-mounted;
- whether the range has a single or double oven or a double oven with a microwave upper oven;
- volume of usable oven space in litres for each oven;
- whether the baking mode is normal bake or normal bake with forced convection;
- exterior oven width in inches.
For counter-mounted range with one or more surface elements and no ovens:
- whether the cooktop is conventional, smooth, solid, modular or tungsten halogen;.
- width in inches
|
APPLIES TO
household freezers that have a capacity of not more than 850 litres (30 cubic feet).
TEST STANDARD
CAN/CSA-C300-00
COMPLIANCE DATE
(February 3, 1995)
July 1, 2001
ENERGUIDE LABEL
required
not required
ENERGUIDE DIRECTORY
available
not available
|
Freezers
Product Class |
Type |
Maximum Annual Energy Consumption
July 1, 2001 (kWh/year)
|
Upright freezers with manual defrost
|
8 |
7.55 AV + 258.3 |
Upright freezers with automatic defrost
|
9 |
12.43 AV + 326.1 |
Chest freezers and all other freezers
|
10 |
9.88 AV + 143.7 |
|
|
|
Product Class
Compact:
|
|
(kWh/year)
|
Compact upright freezers with manual defrost |
16 |
9.78 AV + 250.8 |
Compact upright freezers with automatic defrost |
17 |
11.40 AV + 391.0 |
Compact chest and all other compact freezers |
18 |
10.45 AV + 152.0 |
Compact = Refrigerated volume < 218.6L (7.75 cu.ft.) and overall height < 90 cm (36 in.)
Where AV = Adjusted volume of the freezer in cubic feet = 1.73 Vfreezer |
Requirements for the energy efficiency report, as listed in Schedule IV of the Regulations
- type of product (freezer);
- brand name;
- model number;
- manufacturer;
- name of the organization or province that carried out the freezer verification and authorized the verification mark that will be affixed to the freezer;
- annual energy consumption in kWh;
- type of freezer, using one of type 8 to 10 or 16 to 18 as described in above table;
- total refrigerated volume;
- adjusted volume; and
- freezing capacity in kilograms of ice per 24 hours.
|
|
APPLIES TO
household propane or natural gas ranges with electrical power sources that are used for food preparation and that have one or any combination of:
top or surface cooking;
oven cooking; or
broiling.
TEST STANDARD
None
COMPLIANCE DATE
February 3, 1995
ENERGUIDE LABEL
required
not required
ENERGUIDE DIRECTORY
available
not available
|
Gas ranges
No continuously burning pilot light if product has a cord set
Requirements for the energy efficiency report, as listed in Schedule IV of the Regulations
- type of product (gas range);
- brand name;
- model number;
- manufacturer;
- volume of usable oven space in litres;
- whether the range is built-in or free-standing; and
- whether the broilers are open or closed.
|
APPLIES TO
a household appliance that consists of a clothes washer component and a clothes dryer component located above, below or beside the clothes washer component, that is powered by a single power source and the control panel of which is located on one of the components, and includes a combination clothes washer-dryer.
"Combination clothes washer-dryer" means a household appliance with a clothes washer function and clothes dryer function utilizing the same drum, a common control panel, and
one power source.
TEST STANDARD
1. washer component: CAN/CSA-C360-98
2. CAN/CSA-C360-03
1.2. dryer component: CAN/CSA-C361-92
COMPLIANCE DATE
Washer component:
January 1, 2004
Dryer component:
May 1, 1995
ENERGUIDE LABEL
required
not required
ENERGUIDE DIRECTORY
available
not available
|
Integrated clothes washer-dryers
PRODUCT CLASS |
Minimum Energy Performance Level
January 1, 2004
|
Clothes washers |
See clothes washer minimum modified energy factor (L/kWh/cycle) |
Clothes dryer |
See clothes dryer minimum energy factor (kg/kWh) |
Requirements for the energy efficiency report, as listed in Schedule IV of the Regulations
- type of product (integrated clothes washer-dryer);
- brand name;
- model number;
- manufacturer;
- name of the organization or province that carried out the washer-dryer verification and authorized the verification mark that will be affixed to the washer-dryer;
- washer-dryer annual energy consumption in kWh;
- test group (size category; compact or standard);
- clothes washer modified energy factor in L/kWh/cycle;
- volume of clothes washer basket in litres;
- clothes washer water consumption factor in L/cycle/L;
- maximum wash temperature available: less than or equal to 57.2 °C or greater then 57.2 °C;
- wash-rinse temperature selections featured as listed in Table 5 of CSA 360-03;
- water fill control systems featured: manual or adaptive;
- dryer energy factor in kg/kWh;
- volume of dryer drum in litres;
- type of drying control on the dryer: timed, auto-temperature or auto-moisture;
- clothes washer annual energy consumption in kWh (based on 392 cycles/year);
- clothes dryer annual energy consumption in kWh (based on 416 cycles/year).
|
APPLIES TO
household refrigerators or combination refrigerator-freezers that have a capacity of not more than 1100 litres (39 cubic feet), with the exception of refrigerators that employ an absorption refrigeration system.
TEST STANDARD
CAN/CSA-C300-00
COMPLIANCE DATE
(February 3, 1995)
July 1, 2001 and December 30, 2002
ENERGUIDE LABEL
required
not required
ENERGUIDE DIRECTORY
available
not available
|
Refrigerators and combination refrigerator-freezers
Product Class |
Type |
Maximum Annual Energy Consumption
July 1, 2001; and for Type 3 only (>=14.5 cu.ft. <= 18.4 cu.ft.) December 30, 2002
(kWh/year)
|
Refrigerators and refrigerator-freezers with manual defrost |
1 |
8.82 AV + 248.4 |
Refrigerator-freezers with partial automatic defrost |
2 |
8.82 AV + 248.4 |
Refrigerator-freezers with automatic defrost with top-mounted freezer and without through-the-door ice service, and all refrigerators with automatic defrost |
3 |
9.8 AV + 276 |
Refrigerator-freezers with automatic defrost with side-mounted freezer and without through-the-door ice service |
4 |
4.91 AV + 507.5 |
Refrigerator-freezers with automatic defrost with bottom-mounted freezer and without through-the-door ice service |
5 |
4.60 AV + 459.0 |
Refrigerator-freezers with automatic defrost with top-mounted freezer and with through-the-door ice service |
6 |
10.20 AV + 356.0 |
Refrigerator-freezers with automatic defrost with side-mounted freezer and with through-the-door ice service |
7 |
10.10 AV + 406.0 |
|
|
|
Product Class
Compact:
Compact refrigerated volume < 7.75 cu.ft. and overall height < 36 in.
|
Type |
Maximum Annual Energy Consumption
July 1, 2001 (kWh/year)
|
Compact refrigerators and refrigerator-freezers with manual defrost |
11 |
10.70 AV + 299.0 |
Compact refrigerator-freezers with partial automatic defrost |
12 |
7.00 AV + 398.0 |
Compact refrigerator-freezers with automatic defrost with top-mounted freezer |
13 |
12.70 AV + 355.0 |
Compact refrigerator-freezers with automatic defrost with side-mounted freezer |
14 |
7.60 AV + 501.0 |
Compact refrigerator-freezers with automatic defrost with bottom-mounted freezer |
15 |
13.10 AV +367.0 |
Where AV = Adjusted volume of the refrigerator in cubic feet = Vfresh food + AF (Vfreezer) |
Vfresh food = Volume of fresh food compartment in cubic feet |
Vfreezer = Volume of freezer compartment in cubic feet |
AF |
= |
1.0 for refrigerators without a freezing compartment; |
|
1.44 for a single-door refrigerator with an internal freezing compartment; and |
1.63 for combination refrigerator-freezers. |
Requirements for the energy efficiency report, as listed in Schedule IV of the Regulations
- type of product (refrigerator or combination refrigerator-freezer);
- brand name;
- model number;
- manufacturer;
- name of the organization or province that carried out the refrigerator or refrigerator-freezer verification and authorized the verification mark that will be affixed to the refrigerator or refrigerator-freezer;
- annual energy consumption in kWh;
- type of refrigerator or refrigerator-freezer, using one of type 1 to 7 or 11 to 15 as described in table on previous page;
- volume of the fresh food compartment;
- volume of the freezer compartment, if there is one;
- total volume of the refrigerator or refrigerator-freezer; and
- adjusted volume of the refrigerator or refrigerator-freezer.
|
|
|