Test Procedures to Determine Mechanical Hazards
-Small Components-
Help on accessing alternative formats, such as PDF, MP3 and WAV files, can be obtained in the alternate format help section.
(52K)
Product Safety Reference Manual
Book 5 - Laboratory Policies and Procedures |
Effective
2001-11-30
|
Part B: Test Methods Section, Method
M-00.1 |
Amendment
#29
|
1 Scope
1.1 This method describes a procedure for
performing the Small Component Test on products or the components
of products described in item 13 of Part II of Schedule I to the
Hazardous Products Act (HPA) for children under 3 years of age to
determine if they meet the applicable requirements set out in the
Hazardous Products (Toys) Regulations by observing if the products
or the components could cause obstruction of the pharyngeal orifice
or ingestion or aspiration of the product or any component thereof.
Toy products or components of toy products that are constructed
entirely of soft textile fibre material are exempt. Since the numerical
values of performance measures are based upon regulatory requirements,
the tolerances for these values have been chosen such that no test
parameter is applied to the product that results in a more severe
condition than that specified in the regulation.
2 Applicable Documents
2.1 The Hazardous Products Act (HPA).
2.2 Hazardous Products (Toys) Regulations and other HPA regulations
that include requirements for small components.
2.3 PSL Project Report 2001- 0627: New Method: TEST PROCEDURES
TO DETERMINE MECHANICAL HAZARDS - SMALL COMPONENTS.
3 Sampling
3.1 The following test procedure should
be conducted on the number of specimens provided or received.
4 Apparatus
4.1 Truncated Right Circular Cylinder (Small
Parts Cylinder). See Figure 1.
4.2 A Force Gauge capable of measuring up to 5 N with a precision
of 0.05 N, and a 12.75 mm (±0.50 mm) diameter flat bottom
tip attachment.
4.3 A 35 mm (±0.50 mm) diameter flat bottom 0.45 kg
(+0, -0.005 kg) mass.
5 Testing Procedure
5.1 The procedure shall be as follows:
5.1.1 Attempt to place any product or component of a product
that is separate or that has detached, into the Small Parts Cylinder
without the use of force.
NOTE: The orientation of the product or any component of
the product that is separate or that has detached is important.
Different orientations should be used when performing this test.
5.2 The following additional procedures are for toys only:
5.2.1 After the product or component of the product is inserted
in the Small Parts Cylinder, observe if it is totally enclosed initially,
or by laying a 35 mm diameter flat bottom 0.45 kg mass across the
top of the Small Parts Cylinder.
5.2.2 If the product or component of the product is partially
enclosed in the Small Parts Cylinder or can be manipulated to become
enclosed, then, using a force gauge with a 12.75 mm diameter flat
bottom tip, apply a force not exceeding 4.45 N on top of the component.
If still not totally enclosed, release this force and proceed with
a second attempt of this same force in the same manner but applied
at a different location to the product or component of the product
under test, or by using the 0.45 kg mass with a 35 mm diameter flat bottom.
5.3 Results
5.3.1 Record the description of any product or component of
the product that is totally enclosed in the Small Parts Cylinder
and whether it was totally enclosed with or without force or manipulation
to alter the orientation of insertion. If force or manipulation
was required to enclose the product or component, record the force
and the type of manipulation.
6 Quality Assurance/Quality Control Procedures
6.1 Ensure that all measuring instruments
are functional and are calibrated with traceability to national
or international standards.
6.2 Testing and the results obtained according to this method
include uncertainty associated with the:
- uncertainty of any or all calibrations by an accredited calibration
laboratory of the apparatus stated and used in this method,
- standard uncertainty or standard deviation of a series of
repeated measurements of masses or with instruments stated and
used in this method (documented in the Equipment Record binder),
- a coverage factor (k = 2) to express an expanded uncertainty
(U = kuc, where uc is the combined standard
uncertainty) for a level of confidence of approximately 95%,
assuming normal distribution (Reference: General Guidelines
for Evaluating and Expressing the Uncertainty of Accredited
Laboratories’ Measurement Results, CLAS Reference Document
5, May 1999).
7 Test Report
7.1 The test report shall contain the following
information:
7.1.1 A description of the product to include brand, style,
country of origin, photo and UPC.
7.1.2 The number of sample elements tested.
7.1.3 The results of the tests (conducted in the sequence
presented in section 5 of this test method) with specific details
for any non compliances or potential problems observed.
7.1.4 The analyst's name and signature, as well as the name(s)
and signature(s) of the reviewer(s).
![Truncated Right Circular Cylinder](/web/20061214013630im_/http://www.hc-sc.gc.ca/cps-spc/images/hecs-sesc/prod-test-essai/method/engin-ingen/M_00-image.gif)
|