Guides and Manuals
Ensure the sample is free of dockage.
Ensure the temperature of the sample is between 11oC and 30oC.
If there is visible moisture on the surface of the grain, leave the grain in a sealed plastic container at room temperature until the moisture has been absorbed into the grain.
Ensure your scale is accurate. Follow Tips for effective use of your Model 919/3.5" or 393/3.5" moisture meters.
Ensure you have the right conversion tables.
Moisture meter conversion tables let you convert the temperature and the reading on the meter to percentage moisture content. These tables are updated periodically. To ensure you have the most current table, contact your CGC Regional Head Office or Bob Wallis at the CGC.
You can also get a copy of a CGC fact sheet, Conversion tables for use with model 919/3.5" and 393/3.5" moisture meters. This fact sheet lists sample sizes and conversion tables to be used for most types of grain.
The CGC uses the Model 919/3.5" moisture meter for official testing of grain samples. It operates over 100 of these meters at locations across Canada. The CGC's Grain Research Laboratory (GRL) provides conversion tables for use with these meters.
Every two weeks, the GRL performs a check test on all CGC meters. The check test is performed to ensure that all CGC meters operate within our allowable tolerances of +0.2 percent moisture.
Check test samples are made available to the head offices of all major grain companies. Companies use these to compare the results of one of their meters with all CGC meters. This meter can be used as a standard if a company wishes to establish its own check test system.
Each day that you use your scale and thermometer, check them to verify their accuracy.
For scales, use a set of weights or weigh a sample of a known weight.
For thermometers, ensure there are no separations in the mercury or alcohol columns.
Determine the temperature of each sample and record it.
Test samples when their temperature is between 11oC and 30oC.
Verify the calibration of the meter.
At least every 10 minutes during continuous use
After each sample with intermittent use
Do three tests on each sample.
Do not interchange grain cells between meters. The cell and body are calibrated as a unit and errors may occur if they are interchanged.
Keep the test cell clean.
Check the cell connection to the meter occasionally. To do this,
Put the meter in the CAL position.
Wiggle the test cell.
If the meter needle moves sharply, one or both of
the cell contacts needs replacing. List of meter service
locations.
Check the electronic alignment of a meter at least once a year. To do this, you create three subsamples that give specified readings on your meter, and then you retest these samples on another meter.
Create three subsamples of different sizes. The first should give a meter reading of approximately 75, the second, approximately 50, and the third, approximately 15. Keep the sample temperature the same when using the two meters. Keep the samples in moisture proof containers between tests.
Check these three samples with another meter (preferably a CGC meter) to see if they give similar results
If you are testing samples continuously, check the calibration at least every 10 minutes.
If you are testing samples intermittently, check the calibration before each sample.
Move the On-Off switch to On.
Turn the function knob to Cal (calibrate).
Turn the large knob on the right side of the meter until dial reading 53 is directly beneath the hairline. Dial reading 53 has a red arrow marked Cal.
Rotate the small knob on the left side of the meter until the meter needle reaches the lowest possible position on the left side of the meter scale.
Turn the function knob to Op (operate).
If you are testing samples continuously, check the calibration at least every 10 minutes.
If you are testing samples intermittently, check the calibration before each sample.
Place a weighed and cleaned sample of grain in the warm-up container or dump cylinder.
Insert the thermometer into the grain
sample.
Important : Make sure that the bulb of the
thermometer does not touch the container walls.
Wait one to three minutes to stabilize the thermometer.
Record the temperature of the sample.
If the temperature is . . .
from 11oC to 30oC
Then...
Determine the moisture content.
If the temperature is . . .
under 11oC or over
30oC
Then...
Keep the sample in an airtight container until its
temperature is from 11oC to 30oC. Important:
Wait one to three minutes to stabilize the
thermometer.
Calibrate the meter, if required. Follow Calibrating the meter.
Set the function knob on the moisture meter to Op.
Record the temperature of the grain. Follow Measuring temperature.
Place the loaded dump cylinder on the measuring cell.
Push the release button, which dumps the sample
into the test cell.
Important : If kernels are in
contact with the surface of the inverted cone portion
of the centre post, the sample is probably light
weight, and the meter reading will be inaccurate.
Follow Estimating moisture
content for light weight wheat and barley
samples.
Remove the empty dump cylinder from the measuring cell.
Turn the dump cylinder over, to prepare it for the next sample.
Turn the large knob on the right side of the meter until the needle reaches the lowest position on the left of the meter scale.
Record the dial reading directly beneath the hairline, to the nearest 0.5 of a division.
Return the weighed grain sample to the dump cylinder. Make sure that you do not lose any kernels.
Repeat steps 5 to 11 two more times. That is, take three meter readings.
Calculate the average of the three meter readings.
Look up the percentage moisture on the conversion table for the grain.
If the reading is higher than those on the conversion chart then follow Estimating moisture content for high moisture samples.
Use these procedures for lightweight wheat, oats and barley samples.
Canada Western Red Spring (CWRS) wheat is light weight if it is less than 66 kg/hL or 320 g/0.5 L.
Oats are lightweight if its test weight is less than 48 kg/hL or 220 g/0.5 L.
Barley is lightweight if its test weight is less than 52 kg/hL or 250 g/0.5 L.
Samples of wheat, oats and barley are also considered lightweight if grain touches the surface of the inverted cone portion of the cell post in the measuring cell.
Conversion tables are available for lightweight CWRS, oats and barley. See Conversion tables for use with model 919/3.5 and 393/3.5 moisture meters.
These are the procedures for estimating the moisture content of lightweight samples of Canada Western Soft White Spring (CWSWS), Canada Western Red Winter (CWRW), and Canada Western Amber Durum (CWAD), Canada Western Extra Strong (CWES), and Canada Prairie Spring Red or Canada Prairie Spring White (CPSR and CPSW) wheat.
Test a 225-gram sample using the Procedures for determining moisture content.
Determine the moisture using Moisture Conversion Table Number 9 (Red Spring Wheat, test weight less than 66 kilograms/hectolitres).
Subtract or add depending upon the correction factor for the appropriate class by moisture range according to the following Correction factors table.
Moisture range (%) | CWSWS1 | CWRW2 | CWAD3 | CWES4 | CPSR/CPSW5 |
---|---|---|---|---|---|
10.0 - 12.0 | +0.3 | -0.1 | -0.4 | -0.2 | 0.2 |
12.1 - 14.0 | +0.1 | -0.3 | -0.6 | -0.3 | 0.0 |
14.1 - 16.0 | 0.0 | -0.5 | -0.8 | -0.4 | -0.3 |
16.1 - 18.0 | -0.1 | -0.6 | -0.9 | -0.5 | -0.5 |
18.1 - 20.0 | -0.2 | -0.8 | -1.1 | -0.6 | -0.7 |
1 Canada Western Soft White Spring. 2 Canada Western Red Winter. 3 Canada Western Amber Durum. 4 Canada Extra Strong Red Spring. 5 Canada Prairie Spring Red/White |
Use a 225-gram sample with the appropriate temperature.
A 225-gram sample of light weight CWSWS wheat gives a meter reading of 40.0 at 15oC.
Determine the moisture using Moisture Conversion Table No. 9 (Canada Western Red Spring wheat, weight less than 66 kg/hL).
Conversion Table Number 9 (CWRS, test weight less than 66 kilograms/hectolitre) gives a percentage moisture of 16.2.
Add or subtract the correction factor from the chart for the appropriate class according to the moisture range.
The correction factor from the Correction factors table is -0.1. The corrected moisture for the light weight sample is (16.2 - 0.1) or 16.1%
If the meter reading on a sample is higher than those on the conversion table, use the following procedure to estimate moisture content.
Accurately weigh out a portion of the original sample larger than the quantity required for testing. For example, use 300 grams of red spring wheat, not 250 grams as required for meter testing.
Spread the sample on paper and let it dry at room temperature.
Reweigh the sample.
Calculate the percentage weight loss.
A = original sample weight
B = sample weight after air drying
Percentage loss in weight during air drying = 100 (A - B) / A = C
Mix the sample thoroughly.
Weigh out the amount required for a meter test.
Determine the temperature of the sample.
Determine the total moisture content of the sample
using the following formula.
C = percentage by weight of moisture loss on
air-drying (step 4)
D = moisture content determined by meter (step
8)
Percentage moisture by weight = [(100 - C) x (D/100)] + C
Report the result to the nearest 0.1%.
Calculator for estimating moisture content for high moisture samples
For beans, the damp moisture range is over 18%.
Use a 250-gram sample.
Use the CGC Cranberry Bean Conversion Table Number 2.
Subtract 2.5 from the table result.
Use the CGC Pea Bean Conversion Table Number 2
Subtract 1.1 from the table result.
Use the CGC Pea Bean Conversion Table Number 2
Subtract 1.4 from the table result.
Use the CGC Pea Bean Conversion Table Number 2
Subtract 1.1 from the table result.
Use the Dark Red Kidney Bean Conversion Table Number 2 and add 0.5 to the result.
Read the percentage moisture directly from the table.
Use the Dark Red Kidney Bean Conversion Table Number 2.
Read the percentage moisture directly from the table.
Use a sample size of 250 grams.
Take a reading using Proceduces for determining moisture content.
Apply the regression formula, where T is the sample temperature in degrees Celsius.
Percentage moisture = 0.155 x Meter Reading + 8.03 + {0.1x (22 - T)}
Use the CGC Pea Bean converion Table Number 2.
Subtract 0.3 from the table result.
Use the Dark Red Kidney Bean Conversion Table Number 2.
Read the percentage moisture directly from the table.
The Pea Bean Conversion Table Number 2 shows a sample of 250 grams is required.
A sample of Great northern white beans shows a meter reading of 25 at 18oC. According to the table, the moisture content for Pea beans at this reading is 13.6%.
To adjust this moisture content for Great northern white beans, subtract 1.4.
The moisture content (of the beans) is 13.6 - 1.4, or 12.2.
Most times, you and your elevator operator probably agree on the moisture content of grain delivery, as you do with grade and dockage assessment. When you cannot agree, you or the operator has the right to obtain a binding decision from the CGC. Payment for the grain must be made according to the CGC's decision.
To take advantage of this service, called Subject to Inspector's Grade and Dockage-moisture content only, the following procedure must be followed. The CGC charges a fee for this service.
While the grain is being delivered to the
elevator, the operator must take a representative
sample in the presence of the owner or the
owner's representative, and the sample must be
satisfactory to that person. The sample is not kept
unless the owner or the owner's representative
requests it.
The representative sample must
Weigh at least 300 grams
Be placed in an unbreakable airtight container supplied by the operator of the elevator
Be properly identified with the owner's name
Be marked Subject to Inspector's Grade and Dockage-moisture content only
The elevator operator issues an interim primary elevator receipt.
The elevator operator sends the sample directly to
CGC Industry Services.
The sample must
Be accompanied by a fully completed CGC form IS-12-7 that includes the interim primary elevator receipt number
Have sufficient postage, if sent by mail
CGC Industry Services communicates the official result of the moisture test, which is final and binding, to both the elevator operator and the owner.
This listing is for your convenience to help you find service for your moisture meter. It does not constitute an endorsement by the Canadian Grain Commission of that company, its products or services.
Mongoose Electronics Service Ltd.
10702-100 Street
Grand Prairie AB T8V
3X8
Telephone: (403) 539-4240
Fax: (403) 539-5717
Desna Scales and Control Systems Inc.
412 Manitou Road
SE
Calgary AB T2G 4C4
Telephone: (403) 243-4848
Fax: (403) 243-9338
Email:
info@desnascales.com
www.desnascales.com
Farmtronics
380 Henderson Drive
Regina SK S4N
5W9
Telephone: (306) 721-6455
Fax: (306) 721-2675
Email:
customerservice@farmtronics.com
http://www.farmtronics.com
Dimo's Tool & Die Ltd / LabtronicsR
(Model 919TM)
12 Bangor Avenue
Winnipeg MB R3E 3G4
Telephone: (204)-772-6998
Fax: (204)-772-8938
www.labtronics.ca
Email: halross@halross.com
Labtronics Manufacturing
1168-167 Lombard Avenue
Winnipeg MB R3B
0V3
Telephone: (204) 943-6037
Fax: (204) 947-9199
http://www.halross.com
Quantum Electronics 90
715-10th Street
Brandon MB R7A
4G7
Telephone: (204) 727-7828
Fax: (204) 727-8287
Tri-Met Instruments
Ltd.
760 Erin St.
Winnipeg MB R3G
2W4
Telephone: (204) 774-8889
Fax: (204) 774-6225
Inspection Specialist
Canadian Grain Commission
300-333 Seymour Street
Vancouver BC V6B
5A6
Telephone: (604) 666-8313
Operations Supervisor
Canadian Grain Commission
Bag 5000
(c/o PRG No. 1, Ridley Island)
Prince Rupert BC
V8J 3W8
Telephone: (604) 627-3036
Operations Supervisor
Canadian Grain Commission
6130-4th Street SE,
suite 14
Calgary AB T2H
2B6
Telephone: (403) 292-4210 or 4211
Operations Supervisor
Canadian Grain Commission
103-108 Research Drive
Saskatoon SK S7N
3R3
Telephone: (306) 975-5714
Operations Supervisor
Canadian Grain Commission
1410-C Caribou Street West
Moose Jaw SK
S6H 7S9
Telephone: (306) 692-5855
Operations Supervisor
Canadian Grain Commission
611 Railroad Avenue
Weyburn SK S4H
0A9
Telephone: (306) 848-3350
Operations Supervisor
Canadian Grain Commission
1054 Pembina Highway
Winnipeg MB R3T
1Z8
Telephone: (204) 983-2790
Operations Supervisor
Canadian Grain Commission
559-8th Street, Unit 3
Brandon MB R7A
3X8
Telephone: (204) 726-7665
Canadian Grain Commission
Industry Services
221 N. Archibald
Street
Thunder Bay ON P7C
3Y3
Telephone: (807) 626-1424
Canadian Grain Commission
Industry Services
Bayport Region
235-10 Centre Street
P.O. Box 158
Chatham ON N7M
5K3
Telephone: (519) 436-3190
Canadian Grain Commission
Industry Services
Eastern Region
715 rue Peel, Suite 271
Montréal
QC H3C 4L7
Telephone: (514) 283-7426
Operations Supervisor
Canadian Grain Commission
P.O. Box 4, Station
B
Québec
QC G1K 7A1
Telephone: (418) 648-4636
Operations Supervisor
Canadian Grain Commission
P.O. Box 83
Port-Cartier
QC G5B 2G9
Telephone: (418) 766-4905
Operations Supervisor
Canadian Grain Commission
P.O. Box 84
Baie-Comeau
QC G4Z 2G8
Telephone: (418) 296-4706
For information on moisture testing, contact:
Bob Wallis
Moisture Technician
Canadian Grain Commission
1404-303 Main Street
Winnipeg MB R3C
3G8
Telephone: (204) 983-3331
Email:
bwallis@grainscanada.gc.ca
For information on other aspects of the work of the Canadian Grain Commission, contact:
Communications
Canadian Grain Commission
800-303 Main Street
Winnipeg MB R3C
3G8
Telephone: (204) 983-2770
Toll Free: 800 853-6705